5kW x 2 Dual-Tank Countertop Induction Deep Fryer
Countertop Induction Double Tank Fryer | 5KW*2
Product Specification
How To Operate This Machine
5kW Commercial Dual-Tank Induction Deep Fryer: Six Checks to Control Long-Term Operating Risk
Critical Components Verified
Welds and Dimensions Checked
Solder Joints and Response Tested
Position and Cooling Re-Checked
Insulation, Withstand Voltage and Grounding
Tested and Re-Inspected One by One
All results above are from our own factory. See related pages below.
Production Line Center Manufacturing Machines PCB Assembly Center5kW Commercial Dual-Tank Induction Deep Fryer: Built for Fast-Food Takeout, Canteens, Hotels, Snacks and Desserts
Fast-Food Takeout
Canteens and Hotels
Snacks and Desserts

Frequently Asked Questions
Can the Two Tanks Use Different Heat Settings?
Yes, they adjust separately. The two 9L oil tanks each have an independent oil path, heating coil and basket, and the two knobs adjust independently across levels 1–8. One tank can fry chicken wings while the other fries doughnuts, or one tank can pause; the oil and flavors on the two sides do not mix.
Is 9L per Tank Enough?
Yes—9L per tank is enough for small and medium batches in fast food, takeout, cafés and small canteens, with 18L total across two tanks. The useful capacity comes from the two-basket rotation: one side can unload while the other refries。
Does the Oil Recover Quickly After Loading?
Yes—for normal fast-food, takeout, café and small-canteen batches, the next basket can go in once the oil returns to the selected range. Each 5kW induction head heats its metal tank directly, so energy reaches the oil through the tank wall rather than a separate element, and the two 9L sides let one basket unload while the other cooks.
Can a Standard Outlet Carry It?
No—a standard outlet is not sufficient because each 5kW tank draws about 22.7A at 220V. That current explains why each side needs 4 mm² copper wire and a 32A RCD, and why the two-tank load must be checked as a whole by an electrician rather than added to an existing socket.
Does a Double Tank Use More Electricity?
Not necessarily—the double-tank label describes capacity, not a fixed 10kW draw. The rated total is 10kW only when both tanks run at full load; with one tank on, the load is 5kW, and actual consumption follows how many tanks are heating, for how long and how much idle heat is held. At slow times, running one tank and loading in batches is usually more efficient than keeping both at temperature, so judge use from the operating pattern rather than the word “double.”