Opens in a new tab
+8618024726352
Floor induction griddle
Floor induction griddle
Floor induction griddle 2
Floor induction griddle
Floor induction griddle
Floor induction griddle 2
PRODUCT HIGHLIGHTS

No Open Flame Commercial Induction Griddle | 15kW

Floor Commercial Induction Griddle | 15KW

Value of the 220V Front-to-Back 2-Burner Induction Cooktop
Induction Heat Replaces an Open Gas Flame
Induction heating needs no gas supply, ignition system, or open flame. Grease stays away from flame, reducing one ignition pathway in high-grease service.
Operate Without a Gas Connection
8, 10, 12, and 15 kW models run on 380V three-phase. Food courts, basement kitchens, and open restaurants can match a model to site conditions.
Stable All-Day Production Without an Open Flame
Settings 1–8 give consistent output, so first and last orders match; fixed settings also make gas-restricted procedures repeatable.
01 / SPECIFICATIONS

Product Specification

Product Name
Product Model
Power(Kw)
Voltage(V)
Product Size
Product Material
Hs Code
Floor Commercial Induction Griddle
AT-FLG-008
8kw
380V/3Phase
L700*W750*H800+150mm
SS304 Stainless Steel
8419810000

8KW Electric Requirement

  • Rated at: 12.2A
  • Voltage: 380V (Three-phase)
  • Wire: 2.5mm² Copper Cable
  • Breaker: 16A RCD (Residual Current Device)
Floor Commercial Induction Griddle
AT-FLG-010
10kw
380V/3Phase
L700*W750*H800+150mm
SS304 Stainless Steel
8419810000

10KW Electric Requirement

  • Rated at: 15.2A
  • Voltage: 380V (Three-phase)
  • Wire: 2.5mm² Copper Cable
  • Breaker: 20A RCD (Residual Current Device)
Floor Commercial Induction Griddle
AT-FLG-012
12kw
380V/3Phase
L700*W750*H800+150mm
SS304 Stainless Steel
8419810000

12KW Electric Requirement

  • Rated at: 18.2A
  • Voltage: 380V (Three-phase)
  • Wire: 4mm² Copper Cable
  • Breaker: 25A RCD (Residual Current Device)
Floor Commercial Induction Griddle
AT-FLG-015
15kw
380V/3Phase
L700*W750*H800+150mm
SS304 Stainless Steel
8419810000

15KW Electric Requirement

  • Rated at: 22.8A
  • Voltage: 380V (Three-phase)
  • Wire: 4mm² Copper Cable
  • Breaker: 32A RCD (Residual Current Device)
View All Commercial Induction Griddle
02 / GETTING STARTED

How To Operate This Machine

Step 1
Place your commercial induction cooker in position and connect the power cable based on the required voltage. Make sure all wiring is done correctly before turning on the unit.
Step 2
Once powered on, place your induction cookware on the commercial induction cooker, prepare your ingredients, and get ready to start cooking.
Step 3
Turn the knob from 0 to your desired setting to begin cooking. During the cooking process, simply adjust the knob between levels 1 to 8 to control the heat output to your needs.
Step 4
Once cooking complete,then turn the knob back to 0 to power off the unit. Wipe down and clean the surface of your commercial induction cooker to keep it in top condition.
03 / QUALITY ASSURANCE

No-Open-Flame Commercial Griddle: 6 Factory Tests for Electrical Systems, Cooling, and Final Inspection

01

Incoming Components Matched to the Order

Incoming parts for the no-open-flame griddle are matched to the order, bill of materials, supplier labels, and physical markings before production. Visually similar power modules, capacitors, coils, connectors, or wiring with different ratings can create an electrical risk that is hard to see after assembly. Critical capacitors are sample-tested, and any mismatch in model or rating is held out of the line. This reduces the risk of a wrong electrical component reaching a kitchen that is already relying on a non-gas cooking setup.
02

Solder Quality and Component Polarity Checked

Board production takes place on our own line, where control boards are populated, soldered, and completed with through-hole parts. Bridging, insufficient solder, cold joints, or a reversed component can interrupt control and protection behavior in an appliance where electrical connections carry more of the operating burden. After soldering, the team checks joints and component shift, then verifies orientation, polarity, and full insertion of through-hole leads. Abnormal boards are repaired or isolated, reducing the risk of a board-level fault reaching final assembly.
03

Coil and Airflow Assembly Inspection

An automatic winding machine forms each griddle coil to the model-specific turn count, spacing, and tension, after which dimensions and electrical parameters are checked. During final assembly, the team reconfirms centering, complete insulation, and secure retention, and checks fan direction, connectors, and airflow clearance. A coil or airflow problem in a gas-restricted kitchen can be harder to resolve because the appliance is being used specifically to avoid an open flame. Screening these details before release reduces the risk of unstable heating or restricted cooling in that setup.
04

Wiring and Grounding Safety Tests

During final wiring, technicians verify every conductor against the diagram for the specific model, fully insert and lock each plug, and route wiring away from sharp metal edges and the fan. With the open flame removed, electrical connections and protective earth become a more direct focus of the operating checks. Protective earth is traced to a dedicated grounding point rather than an ordinary structural screw; before the cabinet is closed, the team rechecks missed connections, loose parts, and foreign objects, then performs insulation and dielectric-withstand tests. These checks reduce the risk of an electrical fault being carried into a gas-restricted kitchen.
05

High-Temperature and High-Humidity Validation

Critical control boards and related metal parts are put through moisture removal, drying, high-temperature aging, thermal shock, constant-temperature and humidity exposure, and salt-spray testing as specified. Steam, grease, and repeated heating in a flame-restricted kitchen can work on solder joints, components, and connectors over time. These procedures expose those areas to thermal cycling, moisture, and corrosion before the unit is approved for continuous cooking. The aim is to catch a developing weakness before it becomes an installation problem, not to replace routine cleaning and inspection.
06

Full-Load Operation and Factory Release

At the end of the line, each no-open-flame griddle is powered under the conditions confirmed in the order and checked for heating, cooling, and full-load operation. The team steps through settings 1–8, observes output, fan condition, and any abnormal shutdown, then reconfirms model, power, voltage, frequency, nameplate, appearance, and packaging. A unit that matches on paper can still have a wiring or assembly variation, so release follows the completed check rather than a power-on result alone. This reduces the risk of an electrical or operating mismatch when the griddle is installed in a gas-restricted site.

All results above are from our own factory. See related pages below.

Production Line Center Manufacturing Machines PCB Assembly Center
04 / COOKING APPLICATIONS

No-Open-Flame Commercial Griddle Applications: Food Courts, Hotel Show Kitchens, and Event Catering

Own factory
CE certified
OEM available

Shopping Mall Food Courts

The no-open-flame commercial griddle suits breakfast stalls, burger counters, and teppanyaki-style snack vendors in food courts. Operators can continuously prepare eggs, bacon, burger patties, scallion pancakes, and fried rice. Because the appliance produces no open flame and grease does not contact a flame, it is better suited to enclosed malls that do not permit gas piping but still require commercial griddle capacity.

Hotel Show Kitchens

The appliance suits hotel buffets, all-day dining restaurants, and guest-visible show kitchens. Breakfast egg stations can continuously prepare fried eggs, omelets, and bacon, while lunch and dinner menus can include steak, chicken, fish, and vegetables. With no open flame or gas-combustion exhaust, live cooking is safer in front of guests, and the station does not need space for a gas connection.

Banquets and Event Catering

Banquet halls, exhibition venues, branded events, and temporary catering locations can also use this model. Wherever 380V three-phase power is available, operators can set up a live griddle station for burgers, steaks, sandwiches, pancakes, and griddled vegetables. The appliance requires no gas connection, so temporary kitchens do not need new gas piping and do not introduce an open flame into a densely occupied event space.
hospital kitchen
FAQs

Frequently Asked Questions

We've gathered the most common questions buyers ask before placing their first order — browse through and find the answers that matter most to you.

Yes – its heat output comes from an induction system, offering 30% higher thermal efficiency and speed than gas heating at the same power level. It’s suitable for frequently grilling steaks, hamburger patties, chicken, and sausages. After preheating, settings 1-8 support continuous cooking, allowing you to adjust the power according to different foods.

Yes, because it uses induction heating and controls the heat through power settings, the output at each power level is very stable. It can maintain the set temperature while continuously grilling breakfast eggs, hamburger patties, steaks, and snacks without requiring experience to judge the heat level like with gas heating.

No, because the grease will not come into contact with an open flame. This device has no gas flame, igniter, or ignition electrode, so it will not ignite. Furthermore, our overheat protection device will intervene for secondary protection if the temperature is abnormal. However, it’s still best for operators to control the oil temperature and clean up any accumulated grease promptly.

It uses a 380V three-phase power supply and is equipped with a dedicated circuit that matches the model. For a power of 15kW, a current of approximately 22.8A and a 32A residual current circuit breaker are recommended. (This is suitable for locations with limited gas supply and a three-phase power supply.) Please confirm the voltage, number of phases, and capacity first; 220V sockets are not applicable.

Yes. Although induction cookers eliminate gas combustion and piping, frying pan cooking still produces steam, odors, and heat containing grease. Therefore, shopping malls, hotels, and enclosed kitchens need to be equipped with appropriate exhaust and ventilation systems based on the actual cooking load and local fire and ventilation regulations. The absence of an open flame reduces the danger of gas and flames, but it does not replace a ventilation system.

——07 / Factory quote & RFQ

Partner with a Trusted Commercial Induction Cooker Manufacturer

Whether you need wholesale commercial induction cookers, an OEM product line or a commercial kitchen project configuration, send a focused commercial brief. An ATRX team member can review the product, power, certification and customization requirements before quotation.
Useful information to include: Target country · Product category · Application · Voltage / phase · Estimated quantity · Required certifications · OEM / branding needs

learn more

Please let us know the products you want to know and the information you need to know, and we will contact you as soon as possible.