15kW×2 40L 380V Commercial Chinese Double Wok Cooker
Floor Commercial Induction Chinese Double Wok Cooker | 15KW*2
Product Specification
10KW Electric Requirement (One Burner,One Wire)-(18L)-Pot:500mm
- Rated at: 15.2A
- Voltage: 380V (Three-phase)
- Wire: 2.5mm² Copper Cable
- Breaker: 20A RCD (Residual Current Device)
20KW Electric Requirement (One Burner,One Wire)-(60L)-Pot:800mm
- Rated at: 30.4A
- Voltage: 380V (Three-phase)
- Wire: 10mm² Copper Cable
- Breaker: 40A RCD (Residual Current Device)
25KW Electric Requirement (One Burner,One Wire)-(80L)-Pot:900mm
- Rated at: 38.0A
- Voltage: 380V (Three-phase)
- Wire: 10mm² Copper Cable
- Breaker: 50A RCD (Residual Current Device)
30KW Electric Requirement (One Burner,One Wire)-(105L)-Pot:1000mm
- Rated at: 45.6A
- Voltage: 380V (Three-phase)
- Wire: 16mm² Copper Cable
- Breaker: 63A RCD (Residual Current Device)
How To Operate This Machine
40L Commercial Induction Double Wok Cooker: Six Factory Tests Protect Consistency
Panels Checked First; Thickness and Holes Not Left to Eye Only
Post-Weld Alignment Checked; Edges Not Hidden by Grinding
Control Board Dried First; Solder Joints Checked Board by Board
Coils Machine-Wound and Centered After Mounting
Overheat Protection and Fan/Heat Sink Checked for Continuous Stir-Fry
Full Load, Safety, and Transport Tests Before Release
All results above are from our own factory. See related pages below.
Production Line Center Manufacturing Machines PCB Assembly Center40L Commercial Induction Double Wok Cooker for Restaurants, Cafeterias, and Hotel Banquets
Chinese Restaurants at Peak: Two Woks Clear Orders
Cafeteria Group Meals: Continuous Batches
Hotel Banquets and Open Kitchens: Fresh Cook-to-Order Refills

Frequently Asked Questions
Can Existing 380V Wiring Handle It?
Yes, if the kitchen already has 380V three-phase power and the existing circuits can be checked for this 40L double station. Each 15kW station draws 22.8A and should have a dedicated 6mm² copper circuit with a 32A leakage protector; the electrician should also recheck total capacity, cable length and site distribution.
Can the 15kW Double Wok Produce Wok Hei?
Yes, when the wok is magnetic, preheated and not overloaded. Each 15kW station is intended for high-heat Chinese stir-frying, and the curved coil concentrates heat at the base and lower sides; levels 1–8 move quickly from aroma development to tossing and sauce reduction.
Does Power Weaken Through Lunch and Dinner Service?
No, the station should not lose power through lunch and dinner service when cleaning and cooling are maintained. The two stations have independent power and level control, with fans, heat sinks and overheat protection supporting continuous use, and each unit is checked at full load for temperature rise and protection response. Boards also undergo thermal ageing and thermal shock so output and response remain stable at peak.
What Wok Fits the 700mm Station?
Use a magnetic round-bottom wok designed for a 700mm station. Plain aluminium cannot be used, while aluminium with a magnetic composite base can; the wok should be centred and its base should fit the curved heating zone. An undersized, off-centre or deformed wok can cause uneven heating and pan-detection trips, so the station’s 700mm/40L geometry is the practical boundary.
How Much Power Does Running Both Woks for an Hour Use?
At full power, 15kW×2 for one hour is about 30kWh in theory. Normal cooking is lower because searing, turning down, sauce reduction and pauses do not stay at maximum, while the published maximum thermal efficiency is about 95%, so more heat goes into the wok than the surrounding air.